• WST-Series No-load Strip Tapping Switches
  • WST-Series No-load Strip Tapping Switches
  • WST-Series No-load Strip Tapping Switches
WST-Series No-load Strip Tapping Switches
discuss personally
Model
WSTⅡ5 500/35-6×5
WSTⅡ5 400/35-6×5
WSTⅡ5 400/20-6×5
WSTⅡ5 500/35-4×3
WSTⅡ5 400/20-6×5
WSTⅡ5 500/10-6×5
WSTⅡ5 400/10-6×5
WSTⅡ5 500/10-4×3
WSTⅡ5 400/10-4×3
Basic info
Brand Transformer Parts
Model NO. WST-Series No-load Strip Tapping Switches
Rated voltage 35kV
Rated normal current 500A
Methods of regulation Neutral voltage regulation
number of taps 6
number of position 5
Series WST-Series
Product Detail

Overview

This series of no load switch adopted a new structure, new materials, new technology, the structure is reasonable, feel is good, flexible rotation and in place accurate, etc. Apply to frequency 50, 60 Hz, rated voltage 10 KV, 35 KV and rated current 400 A ~ 600 A oil-immersed power transformer. Can be directly fixed in box cover of the transformer ,under the condition of non-excitation of the primary winding transformer circle number, which changes transformer voltage change, to adjust the subprime output voltage purpose.

Driven through the handle from rotating rack body movement, led moving contacts horizontal rack to change the tap position of the switch, thereby changing the transformer primary winding turns, to change the transformer changes, adjust the secondary voltage of purpose.

outline

If you need to know about more product; welcome contact us.→→→

Know your supplier
Transformer Parts
As a key component in power systems, the stable operation of transformers relies on high-quality accessories. Wone specializes in the sales and supply of transformer accessories, delivering high-quality products and fast response services through an efficient and professional supply chain system. Core Strengths Comprehensive Product Range: Includes insulation materials, cooling components, protection devices, and various structural parts to meet diverse needs. Global Supply Chain Network: Integrates high-quality supplier resources to ensure product stability and reliable delivery schedules. Smart Logistics Management: Utilizes information systems for full-process tracking, improving delivery efficiency and transparency. Professional Technical Support: Offers product selection advice, application consulting, and after-sales maintenance to ensure smooth project execution. Commitment to Sustainability: Prioritizes eco-friendly materials and energy-efficient products, fulfilling corporate social responsibility. Wone is committed to building an efficient, reliable, and sustainable supply chain for transformer accessories, supporting the stable development of the power industry.
Main Categories
Electrical fittings
Business Type
Design/Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should be
Edwiin
07/28/2025
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
1 Hardware Design of Tester Power SupplyThis device uses a standard small - signal generating device to generate small - current signals with the required frequency and phase angle. Then, through the amplifying circuit and phase - modulating circuit, the working power supply is generated.1.1 Power Frequency Sine Wave Small - Current Signal Generating DeviceThe sine wave generating circuit is mainly composed of the waveform generating chip MAX038 produced by MAXIM Corporation of the United States
Ron
07/28/2025
Analysis of Testing Methods for Turns Ratio and Connection Mode of Special Transformers
Analysis of Testing Methods for Turns Ratio and Connection Mode of Special Transformers
1 Error Analysis of Traditional Turn Ratio Testing MethodsThe QJ35 turn ratio bridge and other single-phase-phase-based testers all use the double-voltmeter principle. The QJ35, however, eliminates power supply fluctuation interference via bridge balance. For three-phase transformer ratio testing with a single power supply, corresponding terminals must be shorted and data converted, turning three-phase tests into independent single-phase measurements, with √3 Yd conversion based on connect
Felix Spark
07/28/2025
What are the production processes of special transformers?
What are the production processes of special transformers?
A certain special transformer manufacturing enterprise, which has been producing special transformers such as split - phase - shifting rectifier transformers, rectifier transformers for electrolysis, and transformers for submerged arc furnaces for more than 20 years. Now, an evaluation is made on the production process flow and its characteristics of the special transformers after the company's transformation.1.Production Process Flow Chart of Special TransformersThe production of special transf
Leon
07/28/2025
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!